11.3
General specifications
Parameter
Specification
Compliance and safety
CE
IP rating
The type plate shows the specification.
Refer to section
.
IK rating according to IEC 62262: enclo-
sure
IK10
IK rating according to IEC 62262:
touchscreen
IK08
EMC rating
Class A
11.4
Required tools for installation
Parameter
Specification
Voltage tester
To switch 200 mA of test current
Digital multimeter
Standard
Hoisting equipment or forklift truck
Capable to lift the EVSE safely. Take into
account the dimensions, the mass, the
center of gravity and the maximum tilt
angle. Refer to sections
,
11.5
Maintenance schedule for the service engineer
Part name
Years after startup
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Filter inlet kit
-
R R R R R R R R R R
R
R
R
R
R
Filter outlet kit
-
R I
R I
R I
R I
R I
R
I
R
I
R
Fan cabinet
-
I
I
I
I
R I
I
I
I
R
I
I
I
I
R
Power module
-
I
I
I
I
I
I
I
I
I
R
I
I
I
I
I
DC fuse
-
I
I
I
I
R I
I
I
I
R
I
I
I
I
R
CPI Combo CCS -
I
I
I
I
I
I
I
I
I
I
I
I
I
I
R
Touchscreen/
CPU
-
I
I
I
I
I
I
I
I
I
I
I
I
I
I
R
DC outlet con-
tactor
-
I
I
I
I
I
I
I
I
I
I
I
I
I
I
R
Power supply
-
I
I
I
I
R I
I
I
I
R
I
I
I
I
R
CCS connector
and cable
-
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
•
'I' = Inspection or other procedure
•
'R' = Replacement
Technical data
9AKK108467A6997-EN | 003
55
Summary of Contents for Terra Mobile 44HV
Page 66: ......