![ABB Terra AC Installation Manual Download Page 71](http://html.mh-extra.com/html/abb/terra-ac/terra-ac_installation-manual_346071.webp)
Parameter
Specification
Input AC power connection
1 phase or 3 phase
Input voltage (1 phase)
230 V AC
Input voltage (3 phase)
400 V AC
Standby power consumption
4.6 W
Earth (ground) fault protection
30mA AC, 6 mA DC
Maximum input power (1 phase)
3.7 kW (16 A)
7.4 kW (32 A)
Maximum input power (3 phase)
11 kW (16 A)
22 kW (32 A)
0.25-5 (32) A for MID certified models
11.11.6
AC input specifications (UL portfolio)
Parameter
Specification
Input AC power connection
240 V AC
Standby power consumption
3.6 W
Earth (ground) fault protection
internal 20 mA AC CCID
11.12
General logic interface specifications
Parameter
Specification
Connectivity
Mobile communication with Nano-SIM
socket type M2M (Machine To Machine):
4G (LTE)
Smart meter communication
Modbus RTU (RS485)
Local controller communication
Modbus TCP/IP (secondary)
Ethernet
1x 10/100 BaseT, RJ45 Socket
Extra ethernet (daisy chain)
1x 10/100 BaseT, RJ45 Socket
WiFi (WAN)
IEEE 802.11 b/g/n, 2.4 GHz
Bluetooth
BLE 5.0
RFID
ISO/IEC 14443A, MIFARE
™
Classic, 1K
memory
Compatible mobile device operating sys-
tems
•
Android 4.4 or higher
•
iOS8 or higher
11.13
Cable specifications
11.13.1
AC input cable (IEC portfolio)
Parameter
Specification
EV charger station connection type
Terminal block and screw
Wire size for the terminal block (allowed) Cross section: 10 to 2.5 mm
2
Technical data
BCM.V3Y01.0-EN | 002
71