![ABB Terra 54 Series Installation Manual Download Page 29](http://html.mh-extra.com/html/abb/terra-54-series/terra-54-series_installation-manual_342029.webp)
TERR A 54 / 54HV CHAR G ER
2018- 10- 03
29/40
1. Cut the PE wire of the power cable to the correct length to reach the PE connector.
NOTICE
For safety, it is recommended to make the PE wire longer
than the phase wires. This makes sure that the PE wire stays
connected as longest, if the Terra 54 is moved by a collision.
2. Use wire stripper pliers to remove 20 mm of the insulation from the end of the PE wire.
3. Attach a cable lug to the end of the PE wire.
4. Loosen the bolt of the PE connector.
5. Attach the PE wire onto the PE connector.
6. Tighten the bolt.
5.6.2
Connect power cable
Preconditions:
•
Tools: Wire stripper pliers; wire-end lug pliers; wire-end lugs.
DANGER
Hazardous voltage
Make sure that the main switch of the power supply group
for the product is set to the OFF position. Perform a voltage
check and make sure that the electrical power is discon-
nected from the system.