10.12.8
Alternative base with side entrance
X1
Z
Y2
Y1
Y3
Y4
Y3
X2
X2
A
A
Front side of the base
X1
Width of the base
X2 Distance between the outer
fixation holes
X3 Distance between 2 fixation holes
Y1
Depth of the base
Y2 Depth of the base including the
fasteners
Y3 Distance between the outer
fixation holes
Y4 Distance between the middle
fixation holes
Z
Height of the base
Parameter
Specification
[mm]
[in]
X1
450
17.7
X2
400
15.7
X3
200
7.9
Y1
760
30.0
Y2
752
29.6
Y3
208.5
8.2
Y4
225
8.9
Z
152.4
6
Note:
Guide the AC cables from the rear side of the EVSE to avoid obstacles
and fall hazards.
Technical data
9AKK108466A3703-EN | 001
85