![ABB TA514-SAFETY Operation Manual Download Page 15](http://html1.mh-extra.com/html/abb/ta514-safety/ta514-safety_operation-manual_3386684015.webp)
TA-5 14-S AFET Y AC500-S TRAINING CASE
DOCUMENT ID.
3ADR025217M6801
REV.
B
LANG.
en_US
DATE
2021/09/15
PAGE
15/31
7.3.
Functionality - front panel
No.
Name
Functionality (see circuit diagrams and AC500-S training applica-
tion project for detail)
1
Main power On/Off
switch
Control switch to power on/off the 24V DC power of TA514-
SAFETY
2
Power socket
24V DC input connector for power supply adapter
3
Analog potentiome-
ter(s)
AI 1, AI 2: Adjustable 4 ... 20 mA signal for analog inputs of AI581-S.
4
Channel passivation
simulator switches
T1: Switch to simulate broken wire condition (measurement under-
flow) for analog channel I0 of AI581-S.
T2: Switch to simulate a 24V DC short circuit (channel passivation)
for digital channels I0 and I4 of DX581-S.
5
Input simulator
switches
S6: Switch to activate/deactivate the module passivation of AI581-
S and DX581-S modules through SM560-S Safety CPU program.
S7, S8: Switches connected to DI581-S module to demonstrate
safety digital input behaviour in single channel mode.
S9: Switch to reintegrate all passivated safety module channels.