![ABB Sensyflow FMT700-P Operating Instruction Download Page 23](http://html.mh-extra.com/html/abb/sensyflow-fmt700-p/sensyflow-fmt700-p_operating-instruction_4507023.webp)
Operation
42/14-42-EN Sensyflow
FMT700-P
23
Pos: 13.14 /Bedienung/Durchfluss/FMT700-P/Betrieb mit zwei Messwertaufnehmern @ 33\mod_1253168347124_3101.doc @ 301595 @ 2
5.5
Operation with two flowmeter sensors
Two flowmeter sensors with any nominal diameter can be connected to the supply / evaluation
unit. Both flowmeter sensors (e.g., DN 25 and DN 150) are constantly available for
measurements.
Important (Notice)
Only those measured values for the flowmeter sensor selected via the "SENSOR SELECT"
button are shown on the "DISPLAY" and output as an optional digital and / or analog signal.
The set measuring rate (see section 5.3.1) applies to both flowmeter sensors.
Selecting the required flowmeter sensor
• Press the "SENSOR SELECT" button until the required flowmeter sensor is selected.
• To determine which flowmeter sensor is active, refer to the display to see if it showing
"SENSOR 1" or "SENSOR 2" and / or determine it on the basis of the coding at the 25-pin
D-SUB-socket.
Pos: 14 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @