62
| RMC-100| 2105552MNAE
Figure 4-20: Network communication setup for 1 Network mode
5.
Click
Send
. The device saves the updated configuration.
6.
Click
Restart
. A warning displays to confirm.
Figure 4-21: Warning before interface restart
7.
Click
Yes
.
8.
Click
OK
.
9.
Verify that the configuration is correct. If DCHP is enabled, ensure the RMC has obtained its
required IP parameters (the IP parameter fields must be automatically populated after the
restart).
10.
Ping the device from the WAN or field network. The RMC should reply to the ping from the
network.
11.
If connecting another device to the RMC-100 in daisy chain fashion, configure the device with a
unique IP address in the same subnet as the IP address configured on the RMC.
12.
Verify that you can reach the connected device by pinging its IP address.
4.7
Configure the RMC for 2 Network mode
The RMC in 2 Network mode separates the two Ethernet interfaces into two logical networks (VLANs).
This mode of operation is displayed as: 2 Networks, in the Mode field on the PCCU Networking tab
screen.