![ABB RER620 Technical Manual Download Page 373](http://html.mh-extra.com/html/abb/rer620/rer620_technical-manual_3180373.webp)
1MAC309294-MB F
Section 6
Condition monitoring functions
RER620
367
Technical Manual
6.1.4.7
Circuit breaker spring charged indication
The circuit breaker spring charged indication subfunction calculates the spring charging
time.
The operation of the subfunction can be described by using a module diagram. All the
modules in the diagram are explained in the next sections.
Figure 201:
Functional module diagram for circuit breaker spring charged indication
and alarm
Spring charge time measurement
Two binary inputs,
SPR_CHR_ST
and
SPR_CHR
, indicate spring charging started and
spring charged, respectively. The spring charging time is calculated from the difference of
these two signal timings.
The spring charging time
T_SPR_CHR
is available through the Monitored data view on
the LHMI or through tools via communications.
Alarm limit check
If the time taken by the spring to charge is more than the value set with the
Spring charge
time
setting, the subfunction generates the
SPR_CHR_ALM
alarm.
It is possible to block the
SPR_CHR_ALM
alarm signal by activating the
BLOCK
binary
input.
6.1.4.8
Gas pressure supervision
The gas pressure supervision subfunction monitors the gas pressure inside the arc
chamber.
The operation of the subfunction can be described by using a module diagram. All the
modules in the diagram are explained in the next sections.
This subfunction is not applicable to magnetic actuators.
This subfunction is not applicable to vacuum interruption.
Summary of Contents for RER620
Page 2: ......
Page 22: ...Section 1MAC309294 MB F 16 RER620 Technical Manual ...
Page 88: ...Section 3 1MAC309294 MB F Basic functions 82 RER620 Technical Manual ...
Page 278: ...Section 4 1MAC309294 MB F Protection functions 272 RER620 Technical Manual ...
Page 362: ...Section 5 1MAC309294 MB F Control functions 356 RER620 Technical Manual ...
Page 418: ...Section 7 1MAC309294 MB F Measurement functions 412 RER620 Technical Manual ...
Page 428: ...Section 8 1MAC309294 MB F Recording functions 422 RER620 Technical Manual ...
Page 464: ...Section 9 1MAC309294 MB F Other functions 458 RER620 Technical Manual ...
Page 554: ...Section 10 1MAC309294 MB F General function block features 548 RER620 Technical Manual ...
Page 568: ...Section 12 1MAC309294 MB F Relay physical connections 562 RER620 Technical Manual ...
Page 574: ...Section 13 1MAC309294 MB F Technical data 568 RER620 Technical Manual ...
Page 576: ...Section 14 1MAC309294 MB F Relay and functionality tests 570 RER620 Technical Manual ...
Page 578: ...Section 15 1MAC309294 MB F Applicable standards and regulations 572 RER620 Technical Manual ...
Page 582: ...Section 16 1MAC309294 MB F Glossary 576 RER620 Technical Manual ...
Page 583: ......