Use only the screws included in the mounting kit when mounting the plates and
the angles on the IED. Screws with wrong dimension may damage the PCBs
inside the IED.
5.3.2.2
Mounting procedure for 19” panel rack mounting
M11948-2 v7
IEC04000452-3-en.vsd
1b
1a
2
3
IEC04000452 V3 EN-US
Figure 4:
19” panel rack mounting details
The required torque for the screws is 3.5 Nm.
PosNo
Description
Quantity
Type
1a, 1b
Mounting angles, can be mounted
either to the left or the right side of
the case
2
-
2
Screw
8
M4x6
3
Washer
8
M4x6