Lifting
Obey these instructions and the additional information given in section
:
•
Protect the corners of the inverter station against shock.
•
Lift the inverter station from the four lifting eyes located in the upper corners.
•
The minimum rated loading capacity of each sling is 5 tons.
•
The minimum length of each sling is 5 m.
•
Adjust the lengths of lifting slings so that the inverter station does not tilt during the
lifting.
•
Do not allow lifting slings to scratch the walls or roof. Damaged paint can lead to
corrosion.
•
Use a guide wire attached to a lower corner of the inverter station to prevent rotation.
WARNING!
Ignoring the following instructions can cause physical injury or death, or damage
to the equipment:
•
Use only authorized lifting equipment and personnel.
•
Prevent anybody getting under the load.
•
Do not stand on the roof while fastening the lifting slings or while lifting.
•
Do not throw slings or hooks onto the roof.
22 Storing, lifting and transporting