64 Mechanical installation
Note:
For easy maintenance, do not install the inverter on a higher level than the floor in
front of it. If the inverter is placed higher, the ramp supplied with the inverter cannot be
used when replacing an inverter module.
The wall
behind the unit must be of non-flammable material.
Required tools
The tools required for moving the unit to its final position, fastening it to the floor and
tightening the connections are listed below:
•
crane, fork-lift or pallet truck (check load capacity!); iron bar, jack and rollers
•
Pozidrive and Torx (2.5–6 mm) screwdrivers for the tightening of the frame screws
•
torque wrench
•
set of wrenches and sockets.
Checking the delivery
The inverter delivery contains:
•
inverter cabinet line-up
•
optional modules (if ordered) installed onto the RDCU control units
•
ramp for the inverter module replacement (frame R8i)
•
appropriate inverter manuals and optional module manuals
•
delivery documents.
Check that there are no signs of damage. Manuals and other loose parts
are delivered
inside the inverter. Before attempting installation and operation, check the information on
the type designation label of the inverter to verify that the delivery is of the correct type.
See sections
on page
and
on page
.
Summary of Contents for PVS800-57-0100kW-A
Page 1: ...ABB solar inverters Hardware manual PVS800 57 central inverters 100 to 1000 kW ...
Page 4: ......
Page 22: ...20 Safety instructions ...
Page 64: ...62 Operation principle and hardware description ...
Page 74: ...72 Mechanical installation ...
Page 90: ...88 Electrical installation PE PE PE ...
Page 124: ...122 Maintenance ...
Page 152: ...150 Dimension drawings Frame R7i 3AUA0000083128 ...
Page 153: ...Dimension drawings 151 AC output 3AUA0000083128 ...
Page 154: ...152 Dimension drawings 3AUA0000083128 One DC input Four DC inputs ...
Page 156: ...154 Dimension drawings R8i 8 DC inputs option 8H382 3AXD50000016935 ...
Page 157: ...Dimension drawings 155 R8i AC output terminals 3AXD50000016935 ...
Page 165: ...Dimension drawings 163 2 R8i AC output terminals 3AXD50000015007 ...
Page 173: ...Dimension drawings 171 3 R8i AC input terminals 3AXD50000015006 ...
Page 178: ...176 Dimension drawings ...
Page 180: ...Contact us www abb com solar 3AUA0000053689 Rev H EN EFFECTIVE 2014 07 09 ...