![ABB PT004042 Operation Manual Download Page 58](http://html.mh-extra.com/html/abb/pt004042/pt004042_operation-manual_2838040058.webp)
Operation Manual / Power2 550-M / High-pressure stage
6 Operation and service / 6.4 Stopping the engine
© Copyright 2022 ABB. All rights reserved.
HZTL4058_EN
Rev.F
March 2022
6.4
Stopping the engine
CAUTION
Residual heat in the low-pressure and high-pressure stage
If the residual heat in the low-pressure and high-pressure stage is not suffi-
ciently dissipated by the circulating lubricating oil, machine damage could
occur.
u
Observe the post-lubrication times and the oil pressure specified for
post-lubrication (see chapter Monitoring during operation / Lubricating
oil pressure).
Post-lubrication
Post-lubrication is required.
u
Observe the oil pressure specified for post-lubrication.
Post-lubrication time [min]
20
Table 16: Post-lubrication time
Page
56
/
119