Parameters 97
196.26
Time in ms within one
minute
Sets the number of milliseconds passed since last
minute.
See parameter
.
0 ms
0 ... 59999 ms
Number of milliseconds since last minute.
1 = 1 ms
196.29
Time source status
Shows the status and priority of active time
source.
b1: Aux Time tick received Time tick from the second priority source is
received.
b2: Tick interval is too long Accuracy of inverter’s time is compromised due to
a long tick interval.
b3: DDCS controller
Tick is received from DDCS controller.
b4: Master/Follower
Tick is received from Master/Follower link.
b5: Reserved
-
b6: D2D
Tick is received from D2D link.
b7: FbusA
Tick is received from fieldbus adapter FBA.
b8: FbusB
Not in use.
b9: EFB
Tick is received from embedded fieldbus.
b10: Ethernet
Not in use.
b11: Panel link
Tick is received from PVS-AP-L control unit or the
Drive composer tool.
b12: Ethernet tool link
Tick is received via FENA-11/21 over ethernet
from Drive composer tool.
b13: Parameter setting
Time and date are set with parameters.
b14: RTC
Not in use.
b15: Drive On-Time
Time and date originate from the system clock of
the operating system. The status indicates that
system time was not synchronized with an
external time source for some time and time
keeping might not be accurate.
196.30
System time - days
Reads system date, days since 31.12.1979.
1 = 1.1.1980
0
0 … 65535
1 = 1
196.31
System time - seconds
Reads system time, seconds since 00:00:00
0
0...86399
1 = 1
196.51
Clear fault and event
logger
Setting this parameter to one (1) clears the fault
and event loggers. Parameter value returns to
zero automatically.
-
0 … 65535
1 = 1
No.
Name/Value/Range
Description
Default
FbEq (16b/32b)
Summary of Contents for PRO-33.0-TL Series
Page 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Page 4: ......
Page 8: ...8 ...
Page 12: ...12 Service menu ...
Page 36: ...36 Program features ...
Page 100: ...100 Parameters ...
Page 112: ...112 Tools ...
Page 121: ......
Page 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...