Parameters 63
151.07
Timeout mode
(
Visible only when parameter
is
FSCA-01.
)
Selects the Modbus register access type to reset
the timeout counter. See parameter
None
None
Modbus timeout feature is disabled.
Communication status in parameter
remains in On-line state.
0
Any message
Timeout counter is reset when any Modbus
register is accessed.
1
Ctrl write
Timeout counter is reset when the control word
register or reference register REF1/REF2 are
written to.
For more information, see
FSCA-01 manual
.
2
151.08
IP address 4
(
Visible only when parameter
is
FENA-11/-21.
)
Fourth octet of FENA IP address (0…255)
0
151.08
OK messages
(
Visible only when parameter
is
FSCA-01.
)
Shows the number of valid messages that the
inverter has received.
0
0…65535
Number of valid messages
151.09
Subnet CIDR
(
Visible only when parameter
is
FENA-11/-21.
)
Subnet masks are used for splitting networks into
subnets. A subnet mask is a 32-bit binary number
that is used to split the IP address into a network
address and a host address. Here, the subnet
mask is represented by its CIDR notation, as
shown in the table below.
0
31
255.255.255.254
31
30
255.255.255.252
30
29
255.255.255.248
29
28
255.255.255.240
28
27
255.255.255.224
27
26
255.255.255.192
26
25
255.255.255.128
25
24
255.255.255.0
24
23
255.255.254.0
23
22
255.255.252.0
22
21
255.255.248.0
21
20
255.255.240.0
20
19
255.255.224.0
19
18
255.255.192.0
18
17
255.255.128.0
17
16
255.255.0.0
16
15
255.254.0.0
15
14
255.252.0.0
14
13
255.248.0.0
13
12
255.240.0.0
12
11
255.224.0.0
11
No.
Name/Value/Range
Description
Default
FbEq (16b/32b)
Summary of Contents for PRO-33.0-TL Series
Page 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Page 4: ......
Page 8: ...8 ...
Page 12: ...12 Service menu ...
Page 36: ...36 Program features ...
Page 100: ...100 Parameters ...
Page 112: ...112 Tools ...
Page 121: ......
Page 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...