Electrical installation 69
Environmental sensor installation procedure
To install an environmental sensor:
1. Isolate the inverter from all power sources. Refer to
.
2. Install the FIO-11 Analog I/O extension module. Refer to
and
FIO-11 Analog I/O extension user’s manual
(3AFE68784930 [EN]).
3. To connect the environmental sensor, refer to
Supported environmental sensors
Connection diagrams for the environmental sensors
on page
4. Connect the inverter.
5. Start the inverter.
6. Set the inverter operation to
Disabled
. Refer to
on page
7. Do the set up for the FIO-11 Analog I/O extension module.
•
In the control unit, open
Menu
->
Communication
->
Extension I/O
.
•
Select
FIO-11
as the option module type.
•
To configure the environmental sensor, refer to the
PRO-33.0-TL Service
menu guide
(3AXD50000015823 [EN]).
8. Set the inverter operation to
Enable
.
Summary of Contents for PRO-33.0-TL Series