![ABB Power2 850-M46 Operation Manual Download Page 101](http://html.mh-extra.com/html/abb/power2-850-m46/power2-850-m46_operation-manual_2838038101.webp)
Operation Manual / Power2 850-M / 4.1 Low-pressure stage
4 Disassembly and assembly / 4.6 Removing wall insert
© Copyright 2019 ABB. All rights reserved.
HZTL4062_EN
Revision A
March 2019
Fig. 8: Removing wall insert 2
5. Unplug cable connector (86515) and fix speed measurement cable in wall insert.
6. Fit bracket (90030) with screws (90955) and nuts (90415).
Fit two plates (90031) and secure with plate (90032), screw (90656) and nut (90432).
7. Secure lifting gear to swivel lifting eye (90231).
8. Remove nut (72004) and carefully move out wall insert.
Fig. 9: Removing wall insert 3
9. Fit support angle (90480) with screws (90955) and nut (90415).
10. Put down the wall insert (77000).
11. Remove plate (90032), screw (90656), nut (90432) and plates (90031).
Remove lifting gear and bracket (90030).
12. Remove O-rings (77040 / 79020 / 79021).
13. Loosen screws (77016) and remove diffuser (79000).
Page
15
/
43