2. Cleaning the high-pressure turbine stage (HP stage)
u
If present, open the drain pipe in the low-pressure stage during cleaning.
u
Switch the 3-way valve during cleaning from scavenging air to water supply.
u
Carry out the cleaning process with cleaning parameters according to the specifications
in the following table.
Power2
Water flow rate
[l/min]
Water pressure
(guideline value)
[bar]
Duration of water injection
[min]
845 HP
14.5 ±1.0
3.0
10
Table 11: Cleaning parameters HP
Water flow rate
For an optimum cleaning result, the water flow rate adopted when designing the cleaning
process should be set via the corresponding control valves and monitored by a flowmeter. If
this is not possible, the specified water pressure at the cleaning connection of the tur-
bocharger is to be set as a rough approximation.
3. Cleaning the low-pressure turbine stage (LP stage)
u
If present, open the drain pipe in the low-pressure stage during cleaning.
u
Switch the 3-way valve during cleaning from scavenging air to water supply.
u
Carry out the cleaning process with cleaning parameters according to the specifications
in the following table.
Power2
Water flow rate
[l/min]
Water pressure
(guideline value)
[bar]
Duration of water injection
[min]
845 LP
14.5 ±1.0
1.5
10
Table 12: Cleaning parameters LP
Water flow rate
For an optimum cleaning result, the water flow rate adopted when designing the cleaning
process should be set via the corresponding control valves and monitored by a flowmeter. If
this is not possible, the specified water pressure at the cleaning connection of the tur-
bocharger is to be set as a rough approximation.
4. Drying phase
u
Maintenance of the holding time according to the specifications in the following table
and subsequent adjustment of the desired engine operating point.
Power2
Holding time at reduced load
[min]
845
≥
10
Table 13: Holding time