Operation Manual / Power2 650-M / Low-pressure stage
3 Removal and installation / 3.2 Removing the low-pressure stage
© Copyright 2022 ABB. All rights reserved.
HZTL4065_EN
Rev.E
March 2022
3.2
Removing the low-pressure stage
WARNING
Risk of tipping
If the turbocharger is not sufficiently supported or not supported at all dur-
ing removal and installation, it may tip over and cause severe injury to per-
sonnel or accidents resulting in fatalities.
u
Support the turbocharger at a suitable location.
u
Secure with lifting gear wherever possible.
Fig. 11: Suspension of complete low-pressure stage
u
Remove insulation according to the instructions of the enginebuilder.
u
Disconnect all gas, air, cleaning and oil pipes according to the instructions of the en-
ginebuilder.
u
Disconnect the cable connector from the speed sensor.
u
Attach one lifting gear to each of the two bearing casing suspension points.
u
Loosen the fixing elements on the foot.
u
Lift the low-pressure stage from the engine.
u
Put down the low-pressure stage so that all contact surfaces of the feet make contact.
u
Also place a support made from hard wood beneath the compressor casing.
Page
31
/
119