![ABB Orion 3 Base Original Instructions Manual Download Page 33](http://html.mh-extra.com/html/abb/orion-3-base/orion-3-base_original-instructions-manual_5140033.webp)
2TLC
172289M0201
Rev C
33
www.abb.com/jokabsafety
2018-04-17
8 Diagnostic functions
8.1 Visualisation of the status of the AOPD
A display helps the user control and check the status of the AOPD, in Alignment mode, in normal operation mode and
when troubleshooting. The display consists in four LEDs and a 7-segment display on the active unit.
Figure 32
– LEDs on the display
8.2 Diagnostic messages
Active unit
All the possible cases of visualization are explained in the table below except those relative to the Alignment mode
(see paragraph 6
Display
Status
Description
Action
Interlock
Detection zone free.
OSSD outputs off.
Push the RESET button to return to
normal operation.
Interlock
Beam(s) interrupted.
OSSD outputs off.
Remove the object from the detection
zone and push the RESET button.
OSSD ON
OSSD outputs on.
OSSD OFF
OSSD outputs off.
Normal operation mode,
OSSD OFF, interlock
EDM function activated.
Normal operation mode,
OSSD OFF, interlock
EDM function
deactivated.
Error mode
OSSD error, one or
both.
OSSD outputs off.
Check the wiring and connections of
the OSSD outputs. Make sure that
there is no short-circuit between them
or with the supply voltage.
Then Acknowledge.
If the error persists, contact your
ABB Jokab Safety representative.