Configuration
Reserved IP addresses
Before configuring IP addresses manually, it is important to be aware that some
ranges are reserved by the robot controller. Configuring units or networks that
collide with these reserved addresses will most likely cause network problems.
The following IP address ranges are allocated for internal functions on the controller:
•
192.168.125.0 - 255
•
192.168.126.0 - 255
•
192.168.127.0 - 255
No other robot controller connected network can be on a subnet that overlaps with
any of the above reserved IP addresses. If a subnet mask in the class B range has
to be used, then a private address of class B must be used to avoid any overlapping.
Contact your local network administrator regarding network overlapping. See
section "Communication" in
Technical reference manual - System parameters
.
Note
It is not recommended using leading zeros in dot-decimal notation of IP
addresses. The numbers may wrongly be interpreted as octal numbers. Different
behaviors on virtual and real controllers may be experienced.
Private Network
The Private Network has a static configuration with IP address 192.168.125.1/24
and hosts a DHCP server. The purpose of the Private Network is to connect the
computers within the robot controller as well as I/O networks and process equipment
local to the robot. Many IP addresses are reserved on this network, so it is
recommended that new units get their IP address from the DHCP server.
Note
Never connect another DHCP server to any of the ports connected to the Private
Network. There cannot be two DHCP servers on the same network. It might cause
an erroneous behavior of both internal and external units.
Ability Network
Configuration of the IP settings for the Ability Network shall be done manually
when the controller is equipped with a wired Connected Services Gateway
(DSQC1041) that is connected to an Internet gateway, using an IP address provided
by the network administrator.
Note
On OmniCore E line controllers, the WAN2 port is equivalent to a wired Connected
Services Gateway (DSQC1041).
The IP address configuration is done either in RobotStudio or on the FlexPendant.
Continues on next page
Product manual - OmniCore C30
107
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.7 Ethernet networks on OmniCore
Continued
Summary of Contents for OmniCore C30
Page 1: ...ROBOTICS Product manual OmniCore C30 ...
Page 562: ...This page is intentionally left blank ...
Page 566: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...
Page 604: ......
Page 605: ......