7.5 Replacing SMB battery
Note
The battery low alert (38213
Battery charge low
) is displayed when the battery
needs to be replaced. The recommendation to avoid an unsynchronized robot
is to keep the power to the controller turned on until the battery is to be replaced.
For an SMB board with 3-pole battery contact (RMU101 3HAC044168-001 or
RMU102 3HAC043904-001), the lifetime of a new battery is typically 36 months.
For an SMB board with 2-pole battery contact, the typical lifetime of a new battery
is 36 months if the robot is powered off 2 days/week or 18 months if the robot is
powered off 16 h/day. The lifetime can be extended for longer production breaks
with a battery shutdown service routine. See
Operating manual - IRC5 with
FlexPendant
for instructions.
WARNING
See instructions for batteries,
Safety risks during handling of batteries on page 27
.
Continues on next page
Product manual - Motor Units and Gear Units
81
3HAC040148-001 Revision: K
© Copyright 2011 -2018 ABB. All rights reserved.
7 Maintenance
7.5 Replacing SMB battery
Summary of Contents for MID 1000