Electrical installation: AC input / DC input, motor and brake 51
Power cable connection
AC power cable connection diagram
MicroFlex e190
L1/L
L2/N
L3
L1/L
L2/N
L3
U
PE
PE
PE
PE
(1)
(2)
V
W
U
V
W
R-
R+
UDC-
UDC+
PE
(3)
Optional braking
resistor (see the
chapter
on page
)
Mains filter (optional). See the
chapter
Notes:
– If shielded supply (input) cable is used, and the conductivity of the shield is less than 50% of
the conductivity of a phase conductor, use a cable with a ground conductor or a separate PE
cable (1).
– For motor cabling, use a separate ground cable (2) if the conductivity of the cable shield is less
than 50% of the conductivity of a phase conductor and the cable has no symmetrical ground
conductors. See also section
.
– AC supply (3), 1-phase
200...240 V
(±10%) or 3-phase
200...240 V
phase-to-phase (±10%).
L1 and L2 are used for single phase supply.
The UDC+/UDC- connectors can be
used for common DC configurations.
See page
.
For alternatives, see
(page