6 Installing DAU
6.1 Installation kit
The MACHsense-R kit contains the following:
Item description
DAU
Accelerometers (four)
Mounting pad (four)
Cable (four, 10 m each)
Installation guidelines
The recommended way of installing vibration sensors is to glue the mounting pads into their correct
position on the motor.
·
Recommended glue: Loctite AA326
·
Recommended Activator: Loctite SF7649
·
Recommended cleaner Loctite 7061
Note: Mounting glue is not included in the MACHsense-R package.
Safety Data sheet are available at the Loctite website
http://www.henkel-adhesives.com
.