Appendix C Technical Reference
Sub-Schedule
3BDD011677-600 A
111
Sub-Schedule
Sequence
Sequence Element
Meaning
Range of values
Octets
schedule identifier
0xff
1
transfer version number
0x08 + (0 - 7)
1
schedule version
1 - 0xffff
2
subschema identifier
1 - 0xffff
2
period
1 - 0xffffffff
4
sequence 1
sequence i
sequence m
end of sub-schedule
0
4 * l, I = 1, 2, 3, ...
Meaning
Range of values
Octets
start time
0 - 0xffffffff
4
maximum duration
unused
2
element description 1
see following
3
element description i
see following
3
element description x
see following
3
end of sequence
0
2 * I, I = 1, 2, 3, ...
Meaning
Range of values
Octets
element type: CD2
0xB0 + priority
1
DLCEP address
node.selector
2
Parameters consisting of several bytes must have the Motorola Big-Endian
format.