6.5 Pin calibration
Location of calibration tool
The calibration tool is mounted on the track motion as shown in the figure.
xx2200001158
Required equipment
Note
Article number
Equipment etc.
Attachment screws 9DA183-52
(M10x35), 2 pcs, required. Not in-
cluded with the calibration tool.
3HAC042466-001
Calibration tool
Attachment screw 9DA183-52
(M10x35), 1 pc, required. Not in-
cluded with the calibration tool.
3HAC042467-001
Calibration tool, mirrored
Isopropanol
-
Cleaning agent
Calibrating
Use this procedure to perform fine calibration.
Note/Illustration
Action
WARNING
Make sure no persons are on the track motion
when the carriage is in motion. Also make sure
that the track motion’s cover plates are free from
loose objects, otherwise they can get trapped
between the carriage and the plates.
1
Continues on next page
Product manual - IRT 710
357
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
6 Calibration
6.5 Pin calibration