![ABB IRBP Product Manual Download Page 63](http://html.mh-extra.com/html/abb/irbp/irbp_product-manual_5096063.webp)
CAUTION
If using auto-hatch or other slow processes as safety barrier, then two jumpers
should be added in the SIB harness. See the circuit diagram.
•
TB3:2 to TB31:10
•
TB31:11 to TB31:12
By adding jumpers, the operator only needs to press the start process button
once to start the process.
Systems delivered before March 2019 have these two jumpers installed on
delivery.
Manual Jog control panel
Manually adjustable load position (or Manual Jog) is a control panel fitted between
the robot controller and the positioner.
Manual Jog can be used for:
•
Positioner IRBP K/R
•
Positioner 2 x IRBP L
Continues on next page
Product manual - IRBP /D2009
63
3HAC037731-001 Revision: T
© Copyright 2010-2020 ABB. All rights reserved.
2 System description
2.4.2 External control units
Continued