8.7.2 Calibrating the multi-arc system
Required equipment
Note
Article number
Equipment
Make a pointer that screws into the
tip adapter.
-
Pointer
The point of the pointer should be in
exactly the same position as the
defined TCP, e.g. 15 mm from the end
of the nozzle.
xx1800000747
Used for making a punch mark on the
turning disc and the bearing disc
spigot (if available).
-
Centre punch and hammer
Tool calibration
Start to calibrate the welding tool TCP using BullsEye.
Note
Action
xx1400000898
Change the mass in the tool data from the negat-
ive value to the correct value for your tool, see
figure.
1
xx1800000746
Activate the tool.
2
Continues on next page