6.7.2 Replacing SMB board
WARNING
See
Hazards related to batteries on page 33
Required equipment
Note
There are different variants of SMB units and batteries. The variant with the
3-pole battery contact has longer lifetime for the battery.
It is important that the SMB unit uses the correct battery. Make sure to order the
correct spare parts. Do not replace the battery contact!
Note
Equipment
See
SMB board
Removing the SMB board
Use this procedure to remove the SMB board in the SMB box.
Information
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded space.
1
ELECTROSTATIC DISCHARGE (ESD)
Before handling the unit, see
.
2
Open the cover on the SMB box.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
3
Disconnect the cables.
4
Remove the screws holding the plate.
5
Pull out the plate.
6
Loosen the three screws holding the SMB board.
7
Pull out the SMB board.
8
Continues on next page
230
Product manual - IRBP /D2009
3HAC037731-001 Revision: T
© Copyright 2010-2020 ABB. All rights reserved.
6 Repair
6.7.2 Replacing SMB board
Summary of Contents for IRBP
Page 1: ...ROBOTICS Product manual IRBP D2009 ...
Page 38: ...This page is intentionally left blank ...
Page 70: ...This page is intentionally left blank ...
Page 250: ...This page is intentionally left blank ...
Page 264: ...This page is intentionally left blank ...
Page 314: ...This page is intentionally left blank ...
Page 330: ...This page is intentionally left blank ...
Page 333: ......