![ABB IRBP Product Manual Download Page 171](http://html.mh-extra.com/html/abb/irbp/irbp_product-manual_5096171.webp)
5.3 Maintenance schedule and expected component life
5.3.1 Maintenance schedule
General
This chapter details all maintenance activities recommended for the IRBP. It is
based on the maintenance schedule located at the beginning of the chapter. The
schedule contains information about required maintenance activities including
intervals, and refers to procedures for the activities. Each procedure contains all
information required to perform the activity, e.g. required tools and materials. The
procedures are gathered in different sections and divided according to the
maintenance activity.
Activities and intervals, standard equipment
The sections referred to in the table can be found in the different chapters for every
maintenance activity. The table below specifies the required maintenance activities
and intervals:
Interval
Equipment
Maintenance activity
Running
Positioner harness
Inspection
Running
Current collector
Inspection
Running
Interchange gearbox, oil leak
Inspection
Running
Positioner
Clean
400h
Current collector
Lubrication
40,000h
Gearbox, oil
Lubrication
Battery low alert
i
Battery pack, measurement
system with 2-pole battery
contact, e.g. DSQC633A
Replacement
36 months or battery low alert
ii
Battery pack, measurement
system of type RMU101 or
RMU102 (3-pole battery con-
tact)
Replacement
i
The battery low alert (38213
Battery charge low
) is displayed when remaining backup capacity
(robot powered off) is less than 2 months. The typical lifetime of a new battery is 36 months if the
robot is powered off 2 days/week or 18 months if the robot is powered off 16 h/day. The lifetime
can be extended with a battery shutdown service routine. See
Operating manual - IRC5 with
FlexPendant
for instructions.
ii
The battery low alert (38213
Battery charge low
) is displayed when the battery needs to be replaced.
The recommendation to avoid an unsynchronized robot is to keep the power to the controller turned
on until the battery is to be replaced.
See the replacement instruction for more details.
Product manual - IRBP /D2009
171
3HAC037731-001 Revision: T
© Copyright 2010-2020 ABB. All rights reserved.
5 Maintenance
5.3.1 Maintenance schedule
Summary of Contents for IRBP
Page 1: ...ROBOTICS Product manual IRBP D2009 ...
Page 38: ...This page is intentionally left blank ...
Page 70: ...This page is intentionally left blank ...
Page 250: ...This page is intentionally left blank ...
Page 264: ...This page is intentionally left blank ...
Page 314: ...This page is intentionally left blank ...
Page 330: ...This page is intentionally left blank ...
Page 333: ......