4 Repair
4.3.1. Replacement of cable harness, axes 1-4
255
3HAC022033-001 Revision: K
©
Co
py
rig
h
t 200
4-
201
1 AB
B. All
ri
gh
ts reser
v
ed.
Refitting, cable harness, axes 1-4
The procedure below details how to refit the cable harness, axes 1-4.
12. Remove the cable gland securing the cables to the
arm house.
xx0100000143.wmf
13. Remove the
velcro strap
from the harness at the
cable fixing bracket at the arm house.
Shown in the figure
14. Disconnect
connector R2.M5/6
at the cable division
point.
Shown in the figure
15. Disconnect all connectors at motor 3 and motor 4.
Specified and shown in the figure
Location of cable harness on
page 251
!
16. Gently pull the cable harness out.
Action
Note
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
Turn off all electric power and hydraulic but not the
air pressure to the gearboxes, motors and SMB.
2. In order to facilitate refitting of cable harness,
move the robot to the specified position:
•
Axis 1: 0 degrees
•
Axis 2: 0 degrees
•
Axis 3: 0 degrees
•
Axis 4: 0 degrees
•
Axis 5: +90 degrees
•
Axis 6: no significance
Axes 2 and 3 may be tilted slightly
to improve access.
Continued
Continues on next page