2 Installation and commissioning
2.6.4. Mechanically restricting the working range of axis 3
119
3HAC022033-001 Revision: K
©
Co
py
rig
h
t 200
4-
201
1 AB
B. All
ri
gh
ts reser
v
ed.
2.6.4. Mechanically restricting the working range of axis 3
General
The working range of axis 3 is limited by fixed mechanical stops and can be reduced by
adding additional mechanical stops with 20 graduation in respective direction.
Mechanical stops, axis 3
The illustration below shows the mounting position of the mechanical stops on axis 3.
xx0300000048
The figure shows IRB 7600 but the principle is the same.
A
Additional mechanical stops
B
Fixed mechanical stop
C
Attachment screw M16x60 quality 12.9