Step 2 - Storing the revolution counter setting with the TPU
This section details the second step when updating the revolution counter; storing the
revolution counter setting with the TPU (RobotWare 4.0).
Action
Note
1. Press the button "Miscellaneous" then ENTER to select the service
window.
xx0100000194
2. Select
Calibration
from the
View
menu.
The Calibration window appears.
If there is more than one unit connected to the robot, they will be listed
in the window.
xx0100000201
3. Select the desired unit and choose
Rev Counter Update
from the
Calib
menu.
The Revolution Counter Update window appears.
xx0100000202
4. Select the desired axis and press
Incl
to include it (it will be marked
with an x) or press
All
to select all axes.
5. Press
OK
when all axes that are to be updated are marked with an x.
CANCEL
returns to the Calibration window.
6. Press
OK
again to confirm and start the update.
CANCEL
returns to the Revolution Counter Update window.
7. At this point, it is
recommended
that the revolution counter values are
saved to a diskette.
Not required.
Continued
Continues on next page