Note
Action
xx1200001067
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
5
Use caution and pull out the motor cables.
6
Removing the axis-1 motor
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Lifting accessory (chain): 3HAC15556-1
Attach the lifting accessories.
2
Lifting accessory, motor: 3HAC14459-1.
24 VDC power supply
To release the brakes, connect the 24 VDC
power supply.
3
Connect to R2.MP1-connector:
•
+ = pin 2
•
- = pin 5
CAUTION
The weight of the motor is 27 kg
All lifting accessories used must be sized
accordingly.
4