Note
Equipment
These procedures include references to the
tools required.
Other tools and procedures may be re-
quired. See references to these procedures
in the step-by-step instructions below.
For spare part no. see chapter Spare parts,
section:
•
SMB unit
Removing the SMB unit
Use this procedure to remove the SMB unit.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
1
A
B
C
xx0900000103
Remove the
base cover
.
2
Parts:
•
A: Attachment screws (6 pcs)
•
B: Base cover
•
C: Cable straps, securing the bat-
tery cable (2 pcs)
Cut the
cable straps
securing the battery
cable.
3
Continues on next page
224
3HAC033453-001 Revision: H
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.3.3 Replacing SMB unit
Continued
Summary of Contents for IRB 4600 - 20/2.50