Note
Action
Remove the guide pins and fit the remaining two
screws and washers. Tighten by hand.
Do not tighten with a torque yet.
8
Tightening torque:
Add Loctite 243 to all screws.
9
17 Nm
Tighten the four motor attachment screws.
xx2100000967
Connect the two cable connectors on motor.
10
WARNING
Turn on all:
•
electric power supply
11
Continues on next page
158
Product manual - IRB 365
3HAC079185-001 Revision: A
© Copyright 2022 ABB. All rights reserved.