5 Calibration information
5.1 When to calibrate
When to calibrate
The system must be calibrated if any of the following situations occur.
The resolver values are changed
If resolver values are changed, the robot must be recalibrated using the calibration
methods supplied by ABB. Calibrate the robot carefully with standard calibration,
according to information in this manual.
The resolver values will change when parts affecting the calibration position are
replaced on the robot, for example motors or parts of the transmission.
The revolution counter memory is lost
If the revolution counter memory is lost, the counters must be updated. See
Updating revolution counters on page 248
. This will occur when:
•
The battery is discharged
•
A resolver error occurs
•
The signal between a resolver and measurement board is interrupted
•
A robot axis is moved with the control system disconnected
The revolution counters must also be updated after the robot and controller are
connected at the first installation.
The robot is rebuilt
If the robot is rebuilt, for example, after a crash or when the reach ability of a robot
is changed, it needs to be recalibrated for new resolver values.
The resolver values must be updated if the robot is stopped with the emergency
stop or by breaking a safety chain, and after running in to a mechanical stop.
Product manual - IRB 360
237
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
5 Calibration information
5.1 When to calibrate
Summary of Contents for IRB 360 Series
Page 1: ...ROBOTICS Product manual IRB 360 ...
Page 8: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 156: ...This page is intentionally left blank ...
Page 236: ...This page is intentionally left blank ...
Page 258: ...This page is intentionally left blank ...
Page 276: ...This page is intentionally left blank ...
Page 278: ...This page is intentionally left blank ...
Page 283: ......