5 Calibration information
5.9. Serial Measurement Board memory
3HAC030005-001 Revision: -
186
©
Copyri
ght 200
6 ABB
.
All ri
ghts res
erved.
Delete SMB data
This section describes how to delete the data stored on the SMB memory or the controller
memory, when creating spare parts.
Related information
Operating manual - RobotStudio Online.
Operating manual - Service Information System.
Application manual - Motion performance.
Action
1. On the ABB menu, tap Calibration and tap to select a mechanical unit.
2. Tap SMB memory and then tap Advanced.
The following functions are available:
•
Clear Cabinet Memory
•
Clear SMB Memory
3. Tap Clear Cabinet Memory if the controller should be replaced and used as a spare
part.
A list of the SMB data stored in the controller is displayed. Tap Clear to delete the
memory for the selected robot. Repeat the procedure for all robots in the controller
memory.
4. Tap Clear SMB Memory if the SMB should be replaced and used as a spare part.
A list of the SMB data stored is displayed. Tap Clear to delete the memory for the
selected robot. Repeat the procedure for all robots using this SMB board.
Continued