4 Repair
4.6.1. Replacement of SMB unit
3HAC022031-001 Revision: C
114
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
4.6 Frame and base
4.6.1. Replacement of SMB unit
Location of SMB unit
The SMB unit (SMB = serial measurement board) is located on the left hand side of the base,
as shown in the figure below.
A more detailed view of the component and its position may be found in chapter
and exploded views on page 181
in part 2 of the Product manual.
Note that the robot is shown with the SMB cover already removed!
xx0200000451
Required equipment
A
Cable, battery/SMB board
B
Battery
C
Serial measurement board
D
Lock nuts
Equipment
Spare part no. Art. no.
Note
Gasket, base cover
3HAB 5537-1
Must always be replaced!
Serial measurement unit
3HAC17396-1
Continues on next page