5.1.2 Calibration methods
Overview
This section specifies the different types of calibration and the calibration methods
that are supplied by ABB.
Types of calibration
Calibration method
Description
Type of calibration
Axis Calibration or
manual calibration
i
The calibrated robot is positioned at calibration
position.
Standard calibration data is found on the SMB
(serial measurement board) or EIB in the robot.
Standard calibration
For robots with RobotWare 5.04 or older, the
calibration data is delivered in a file, calib.cfg,
supplied with the robot at delivery. The file
identifies the correct resolver/motor position
corresponding to the robot home position.
CalibWare
Based on standard calibration, and besides
positioning the robot at synchronization posi-
tion, the Absolute accuracy calibration also
compensates for:
•
Mechanical tolerances in the robot
structure
•
Deflection due to load
Absolute accuracy calibration focuses on pos-
itioning accuracy in the Cartesian coordinate
system for the robot.
Absolute accuracy
calibration (option-
al)
Absolute accuracy calibration data is found
on the SMB (serial measurement board) in the
robot.
For robots with RobotWare 5.05 or older, the
absolute accuracy calibration data is delivered
in a file, absacc.cfg, supplied with the robot at
delivery. The file replaces the calib.cfg file and
identifies motor positions as well as absolute
accuracy compensation parameters.
A robot calibrated with Absolute accuracy has
a sticker next to the identification plate of the
robot.
A robot calibrated with Absolute accuracy has
the option information printed on its name
plate.
To regain 100% Absolute accuracy perform-
ance, the robot must be recalibrated for abso-
lute accuracy after repair or maintenance that
affects the mechanical structure.
xx0400001197
Continues on next page
806
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
5 Calibration
5.1.2 Calibration methods
Summary of Contents for IRB 1200
Page 1: ...ROBOTICS Product manual IRB 1200 ...
Page 156: ...This page is intentionally left blank ...
Page 896: ...This page is intentionally left blank ...
Page 898: ...This page is intentionally left blank ...
Page 905: ......