3.4 Replacement/changing activities
3.4.1 Replacing the battery pack
Note
The battery low alert (38213
Battery charge low
) is displayed when remaining
backup capacity (robot powered off) is less than 2 months. Typical life of a new
battery is 36 months if the robot is powered off 2 days/week, or 18 months if the
robot is powered off 16 hours/day. The life can be extended (approximately 3
times) for longer production breaks by a battery shutdown service routine. See
the operating manual for the robot controller.
Location of battery pack
The battery pack is located as shown in the figure.
xx1300002574
Continues on next page
134
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
3 Maintenance
3.4.1 Replacing the battery pack