3.3 Inspection activities
3.3.1 Inspecting the robot paint
General
For robots with protection type Hygienic, there is a risk of surface corrosion or
paint peeling in case of mechanical damage to the coated surface. Therefore, it is
important to regularly inspect robot surfaces for any paint breaking or damage.
Required tools and equipment
Note
Spare parts
Equipment
Lint free cloth
White
3HAC036639-001
Touch up paint Clean Room/Hy-
gienic
Inspection, robot paint
Description
Action
Visually inspect the robot surface paint for
any paint breaking.
1
Use a lint free cloth.
If there is paint breaking, clean the surface
so that it is free from oil and grease.
2
3HAC036639-001
Use Touch up paint Clean Room/Hygienic,
white to paint any damaged surfaces.
Note
Always read the instruction in the product
data sheet in the paint repair kit for Clean
Room/Hygienic.
3
Product manual - IRB 1200
119
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
3 Maintenance
3.3.1 Inspecting the robot paint