Attachment screws (16 pcs)
B
Gearbox, axis 3
C
Lower arm
D
Required equipment
Note
Equipment
The content is defined in the section
Standard toolkit
These procedures include references to the tools
required.
Other tools and procedures may be re-
quired. See references to these proced-
ures in the step-by-step instructions be-
low.
For removing residues of Loctite.
Loctite 7063
Loctite 574
Removing the upper arm
Use this procedure to remove the upper arm.
Information
Action
Move axis 5 to a 90° position.
1
DANGER
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
2
CAUTION
Always cut the paint with a knife and grind
the paint edge when disassembling parts
of a Clean Room robot! See
3
Continues on next page