9.10
Nozzle ring compression PD
For the nozzle ring (56001) to be fixed during operation, it must be clamped between the
heat shield (42400) and the turbine casing (51000).
Fig. 53: Nozzle ring compression PD
Product
Compression PD [mm]
A150
-0.17 ... 0.17
A155
-0.17 ... 0.17
Table 43: Permitted nozzle ring compression PD
42001
Bearing casing
51000
Turbine casing
42400
Heat shield
56001
Nozzle ring
1. Measure dimensions A, B, and S on cleaned surfaces.
2. Calculate compression (PD).