Operation Manual / 4 Product description / A130-H.. - A140-H
7 Eliminating malfunctions / 7.4 Malfunctions when stopping
© Copyright 2017 ABB. All rights reserved.
HZTL4030_EN
Revision D
May 2017
7.4
Malfunctions when stopping
Runout noises
Possible causes
Remedy
Turbochar-
ger
Turbocharger contaminated Clean (see chapter
Bearing damaged
Check clearances (see chapter
outside the tolerance or if in doubt, contact an
ABB Turbocharging Service Station.
Rotor rubbing
). If clearances are outside the tol-
erance or if in doubt, contact an ABB Turbochar-
ging Service Station.
Foreign object in the tur-
bocharger
Dismantle turbocharger (see chapter
). In case of damage, re-
place the corresponding parts or contact an ABB
Turbocharging Service Station.
Table 24: Malfunctions when stopping – Runout noises
Runout time too short
The runout time must be noted down as a reference. Because the runout time depends on
the oil viscosity, the runout time must always be measured at the same oil temperature.
If the runout time is significantly shorter in comparison to a previous measurement, the fol-
lowing table must be observed.
Possible causes
Remedy
Turbochar-
ger
Turbocharger contaminated Clean (see chapter
Bearing damaged
Check clearances (see chapter
outside the tolerance or if in doubt, contact an
ABB Turbocharging Service Station.
Rotor rubbing
). If clearances are outside the tol-
erance or if in doubt, contact an ABB Turbochar-
ging Service Station.
Foreign object in the tur-
bocharger
Dismantle turbocharger (see chapter
). In case of damage, re-
place the corresponding parts or contact an ABB
Turbocharging Service Station.
Table 25: Malfunctions when stopping – Runout time too short
Page
54
/
91