Operation Manual / TPS44-F.. - TPS61-F..
Removal and installation
7
Remove the turbocharger
7.3
Page 87
© Copyright 2016 ABB. All rights reserved.
Sept
em
ber
2016
H
ZT
L2412_
EN
R
ev
is
ion
F
Remove the turbocharger
7.3
Disconnect all exhaust gas and air lines according to the instructions
of the enginebuilder.
Version with water-cooled bearing casing:
Disconnect the water pipes according to the instructions of the en-
ginebuilder.
If present, remove hard insulation as follows:
Remove screws and sheet metal (B) from the bearing casing insula-
tion.
Remove the remaining screws from the bearing casing insulation (A).
Pull the bearing casing insulation up and off. The bearing casing insu-
lation can be compressed to facilitate the removal process.
Unplug the cable connector from the speed sensor.
Attach lifting gear to bearing casing.
If a gas outlet bend is present, sling lifting gear around it or secure it to
the lifting gear with a swivel lifting eye (C).
Loosen the fixing screws (D) on the bearing casing.
Lift the turbocharger from the engine and put it down.
Cover oil connections.
7.3