![ABB HT564586 Operation Manual Download Page 75](http://html1.mh-extra.com/html/abb/ht564586/ht564586_operation-manual_3330525075.webp)
Operation Manual / 4 Product description / A100-L
6
Periodic maintenance
Page 45 / 111
© Copyright 2016 ABB. All rights reserved.
HZTL4034_EN
Revision F
June 2016
Volume of water per cleaning process
Product
Quantity [dm
3
]
A165-L
2.0
A170-L
2.0
A175-L
3.0
A180-L
3.0
A185-L
3.0
A190-L
3.0
Table 12: Volume of water per cleaning process
The filling time is 4 ... 15 seconds.
Checking the filter plug
Figure 18: Filter plug view
Disassembly and checking of the filter plug (81125) is required if, 20 seconds after the clean-
ing process, water is still visible in filler opening B.
Loosen and remove the filter plug (81125) with box spanner
Clean the drill holes of the plug
Fit filter plug (81125).
Part number
A165-L
A170-L
A175-L
A180-L
A185-L
A190-L
81125
G1/2"
45 Nm
G1/2"
45 Nm
G1/2"
45 Nm
G1/2"
45 Nm
G1/2"
45 Nm
G1/2"
45 Nm
Table 13: Tightening torques (81125)