4.5
CAUTION
Stopping the engine of oil-cooled turbocharger version
Heat in the turbocharger must be dissipated by the further circulating
lubricating oil.
Post-lubricate for 15 … 20 minutes.
Maintain oil pressure of 0.5 … 1.0 bar for post-lubrication.
CAUTION
Stopping the engine of water-cooled turbocharger version
Heat in the turbocharger must be dissipated.
Allow turbocharger cooling water to run for 15 … 20 minutes after
stopping engine.
Allow oil lubrication to continue running until rotor comes to a stop.
Further post-lubrication is not required and not recommended.