Operation Manual / 4 Product description / A130-M.. - A145-M..
8
Dismantling and fitting
Page 93 / 115
© Copyright 2015 ABB. All rights reserved.
HZTL4031_EN
Revision C
February 2016
8.15
Installing the compressor casing
Fitting the wall insert and the diffuser
A130 - A140
A145
Part number
A130
A135
A140
A145
79041
M6
8 Nm
M6
8 Nm
M6
8 Nm
M6
8 Nm
Table 40: Tightening torque (79041)
Always replace the O-ring (77005) (see section Spare parts).
A130 - A140
1. Fit a new O-ring (77005).
2. Install the wall insert (77000) in the compressor casing.
3. Secure the diffuser (79000) with fixing discs (79040) and screws (79041).
A145
1. Attach the lifting beam (90258) to the wall insert (77000).
2. Attach swivel lifting eyes (01) to lifting beam.
3. Fit a new O-ring (77005).
4. Install the wall insert (77000) in the compressor casing.