398 Configuration
How to configure mute time for SBC speed limit detection
Example
1
: SBC speed limit (parameter
)
is reached with the SS1 function (or
SSE with emergency ramp), a negative SBC delay (parameter
is configured with the SS1 function:
•
With an encoder
: parameter
=
20 ms
•
Without an encoder
: parameter
=
20 ms
.
Note
) is positive or zero
(
0 ms
), the SBC and STO functions are activated at the same time.
Example
2
) is reached in the
STO function (and SSE with immediate STO), requires an encoder:
•
With an encoder
: parameter
=
20 ms
.
Time
Speed
SBC delay elapsed, STO activated
= 20 ms
= 90 rpm
SBC speed
limit reached
Mute time elapsed, SBC activated
= -15 ms
Time
Speed
= 20 ms
= 90 rpm
SBC speed
limit reached
Mute time elapsed, SBC activated
STO activated
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...