182 Safety functions
Safe speed monitor (SSM)
The SSM function provides a safe output signal to indicate whether the motor speed
is between user-defined limits. There are four separate SSM functions
(SSM1...SSM4) with separate monitoring limits and indications. Several SSM
functions can be active at the same time.
You can configure the SSM function to be permanently on or off, or to be activated
externally from the FSO module I/O or from a safety PLC.
You can use the SSM function with a safety encoder or with a safe speed estimate.
With an encoder, the FSO module is always aware of the exact motor speed. Without
an encoder, the speed information is valid only when the drive is modulating (see
section
SSM with a safe speed estimate
).
Note
: If there is a fault in the speed data and the SSM function is the only active
safety function, this does not trip the drive. This only removes the SSM indication and
generates a warning to the drive.
The operation of the SSM function is described in the time diagrams and tables
below. The SSM1 function is used as an example. For configuration, see section
A
SSM1 limit positive (parameter
B
SSM1 limit negative (parameter
)
SSM limits (A and B)
SSM1 state &
indication
SSM1 request
Motor speed
Time
A
4
1
B
2
3
5
6
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...